Scope of certification
Model | Voltage(V) | Current(A) | Power(W)max |
GJ100WD-xxxyyyyW1 / GJ100WD-xxxyyyyW2 | 9.0-14.5 | 0-8.0 | 96.0 |
15.1-58.0 | 0-6.62 | 100.00 |
·Safety & EMC&AC pin
√IEC62368-1(CB/II)、IEC62368-1(CB/I)
√UL62368-1(II)、UL62368-1(I)
√EN62368-1(II):CE/GS/UKCA/SAA
√EN62368-1(I):CE/GS/UKCA/SAA
√GB4943.1(II)、GB4943.1(I)
√Fcc part15 B/EN55032/EN55035/EN55024
√Cert:USA/Europe/Germany/UK/Australia/China
FEATURE | |
Protection functions | OCP/SCP/OVP/OTP |
Efficiency level | DOE-VI/CEC-VI/ERP-VI |
Altitude | 5000M |
Operational temperature | -10-35℃ |
Surge | 1KV/4KV(2pin);1/2KV(3pin) |
EFT | 1KV |
ESD | 8/4KV |
Y-cap Y | 1Y |
CC or CV mode |
CC/CV |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |